Design & Sizing

Solar Single Line Diagram (SLD) Explained, Component by Component

SolarDraft team · · 6 min read

Rows of solar panels with a walkway between them on a commercial roof, designed in SolarDraft

A solar Single Line Diagram (SLD) is a simplified electrical drawing that shows how every part of a solar system connects — from the panels to the inverter, the protection devices, the meters and the grid — using one line to represent each circuit.

For homeowners, the SLD is one of the documents in the DISCOM file. For EPCs, it is far more: the drawing the installation crew wires to, the document the DISCOM inspector checks against, and the record anyone servicing the system will rely on for 25 years. This guide explains what an SLD shows, walks through each component from DC to AC, shows a simplified example for a rooftop system, and lists the mistakes that delay approvals.

Key points

  • An SLD shows the components, their ratings, how they connect, where protection and isolation sit, and how the system is earthed.
  • A typical grid-connected rooftop runs: PV array → DC distribution box → inverter → AC distribution box → meters → grid, with earthing on both sides.
  • DISCOMs commonly ask for an SLD with the net-metering application and check the installation against it at inspection.
  • The most common problems are missing protection devices, unstated ratings, unclear earthing and an SLD that doesn't match what was installed.

What “single line” means

A real electrical circuit has two or more conductors — positive and negative on the DC side, phase and neutral (or three phases) on the AC side. An SLD draws each circuit as a single line so the whole system fits on one page and can be read at a glance. The ratings, device types and connection points are written next to each symbol. Detailed wiring diagrams, cable schedules and string layouts sit alongside it for the installation team.

Why the SLD matters

Who uses itWhat for
DISCOMTo check the connection, protection and metering before approving net metering
Installation crewTo wire the system exactly as designed
InspectorTo verify that the installed devices match the approved design
Service technicianTo understand the system years later when something needs fixing
CustomerAs part of the system's documentation for warranties and resale

A simplified rooftop SLD

The diagram below shows the main blocks of a typical single-phase, grid-connected rooftop system. Real SLDs use standard electrical symbols and state the rating of every device.

Simplified single line diagram of a grid-connected rooftop solar system Power flows from the PV array through the DC distribution box to the inverter, then through the AC distribution box and solar meter to the main distribution board, where home loads are connected, and through the bidirectional net meter to the DISCOM grid. The PV array, DC and AC sides are earthed. DC SIDE AC SIDE PV arrayDC distribution boxGrid-tied inverterAC distribution box Solar generation meterMain distribution boardBidirectional net meterDISCOM grid Home loads Panels in strings, e.g. 6 × 545 WpDC fuses · DC SPD · DC isolatorMPPT · anti-islanding protection MCB · AC SPD · RCCBWhere the DISCOM requires itSolar and grid supply meet here Records import and exportLT supply to the buildingLights, fans, AC LA / frameearthDC earthAC earth
Simplified single line diagram of a grid-connected rooftop system. Actual devices, ratings, earthing and meter positions depend on the design and the DISCOM's rules.

The components, from DC to AC

ComponentWhat it doesWhat the SLD should state
PV arrayConverts sunlight into DC powerPanel model and wattage, panels per string, number of strings
DC cablesCarry DC power from the arrayCable type and size
DC distribution box (DCDB)Protects and isolates the DC sideFuse ratings, DC surge protection device (SPD), DC isolator rating
InverterConverts DC into grid-synchronised AC; shuts down if the grid failsMake, model, AC rating, number of MPPTs, phase
AC distribution box (ACDB)Protects and isolates the AC outputMCB or MCCB rating, AC SPD, RCCB/ELCB rating
Solar generation meterMeasures total solar generation, where requiredMeter type and position
Bidirectional net meterRecords units imported from and exported to the gridPosition at the supply point
Earthing and lightning protectionCarries fault and surge currents safely to groundEarth pits for the DC side, AC side and lightning arrester, as specified
“The SLD is the promise the installation has to keep. If the two don't match, the inspection won't pass.”

How to read an SLD in five steps

  1. Start at the array — count the strings and panels per string, and check the panel rating.
  2. Follow the DC side — find the fuses, the surge protection device and the isolator that lets the array be disconnected safely.
  3. Check the inverter — its AC rating should suit the array, and the number of strings should match its MPPT inputs.
  4. Follow the AC side — find the breaker, AC surge protection and residual-current protection between the inverter and the building's supply.
  5. Finish at the meters and earthing — confirm where generation and net metering are measured and how each side is earthed.

What DISCOMs and inspectors look for

Requirements differ between DISCOMs, so always check the local format and any specific devices they ask for. Our DISCOM approval guide covers the full process.

Common SLD mistakes

MistakeWhy it causes trouble
Generic SLD reused from another jobRatings and string counts don't match the installation
Missing surge protection or isolatorSafety gap; often flagged at inspection
Device ratings not statedThe inspector can't verify the protection
Earthing not shown clearlyQuestions about safety and lightning protection
Capacity differs from the applicationApproval and subsidy delays
Changes on site not reflectedThe as-built system no longer matches the drawing

SLDs for other system types

Generating the SLD from the design

An SLD drawn by hand for every job is slow and easy to get wrong. When it is generated from the same design that produced the layout and the proposal, the capacity, strings and equipment always match. SolarDraft's Solar 3D Design produces a Single Line Diagram, PV array and string route drawings and a Structure BOM from the 3D model, and the proposal carries the same capacity — so the DISCOM file, the crew's drawings and the customer's proposal all tell the same story.

New to the documentation side of solar? See what a solar EPC does and common mistakes new EPCs make.

FAQ

Is an SLD required for net metering?

Most DISCOMs ask for an SLD with the application or the work completion documents. Check your DISCOM's current checklist.

Who prepares the SLD?

The EPC or its design engineer prepares it from the system design, and it should be updated if anything changes on site.

What is the difference between an SLD and a wiring diagram?

An SLD shows the system on one page with one line per circuit and the key ratings. A wiring diagram shows every conductor and terminal in detail for the installers.

Why are the DC and AC sides earthed separately?

Separate earthing for the DC side, the AC side and the lightning arrester is common practice on Indian rooftops and is often specified by DISCOMs and scheme guidelines. Follow the local requirement and show it on the SLD.